<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: DICOM Query/Retrieve Sensor

The DICOM Query/Retrieve sensor monitors the C-FIND capability of Digital Imaging and Communications in Medicine (DICOM) capable systems and devices. It sends a C-FIND request or Modality Worklist (MWL) query to the target device and counts all found items.

i_round_blueYou can specify search levels to only count specific items.

DICOM Query/Retrieve Sensor

DICOM Query/Retrieve Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: DICOM Query/Retrieve
  • French: Requête/récupération (DICOM)
  • German: DICOM-Abfrage
  • Japanese: DICOM クエリ/取得
  • Portuguese: Consulta/recuperação DICOM
  • Russian: Запрос/получение DICOM
  • Simplified Chinese: DICOM 查询/检索
  • Spanish: Consulta/Recuperación DICOM

Remarks

Consider the following remarks and requirements for this sensor:

Remark

Description

Performance impact

This sensor has a high performance impact. We recommend that you use no more than 200 of this sensor on each probe.

.NET 4.7.2 or later

This sensor requires .NET 4.7.2 or later from Microsoft on the probe system. In a cluster, install it on every cluster node.

i_round_redIf the framework is missing, you cannot create this sensor.

i_square_cyanFor more information, see the Knowledge Base: Which .NET version does PRTG require?

IPv6

This sensor supports IPv6.

Basic Sensor Settings

Basic Sensor Settings

Basic Sensor Settings

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • dicom
  • query
  • retrieve

i_square_cyanFor more information about basic sensor settings, see section Sensor Settings.

DICOM Connection

DICOM Connection

DICOM Connection

Setting

Description

Calling Application Entity Title

Enter the Application Entity Title (AET) of PRTG to initialize a DICOM connection.

i_round_blueThe AET is case-sensitive and does not support special characters.

Called Application Entity Title

Enter the AET of the target system to initialize a DICOM connection.

i_round_blueThe AET is case-sensitive and does not support special characters.

Port

Enter the port of the DICOM interface to use for the connection. The default port is 104.

Timeout (Sec.)

Enter a timeout in seconds for the request. Enter an integer. The maximum timeout value is 900 seconds (15 minutes).

i_round_blueIf the reply takes longer than this value, the sensor cancels the request and shows a corresponding error message.

Query/Retrieve Settings

Query/Retrieve Settings

Query/Retrieve Settings

Setting

Description

C-FIND Level

Define the search level of the C-FIND request:

  • Patient: Retrieve data from the patient column via C-FIND. Enter a search key below.
  • Study: Retrieve data from the study column via C-FIND. Enter a search key and a modality below.
  • Series: Retrieve data from the series column via C-FIND. Enter a search key and a modality below.
  • Worklist: Use an MWL query to retrieve data from the worklist. Enter a filter field, a filter string, and a channel field below.

Search Key

This setting is only visible if you select Patient, Study, or Series above.

Enter a key that you want to search for, for example, an instance Unique Identifier (UID), series UID, patient UID, or enter an asterisk (*) to search for all items. Enter a string.

Modality

This setting is only visible if select Study or Series above.

Enter a modality in short form that you want to search for, for example, CT, MRI, US, or enter an asterisk (*) to search for all modalities. Enter a string.

Filter Field

This setting is only visible if you select Worklist above.

Define a field of the worklist that you want to filter for:

  • Station AET
  • Station Name
  • Modality

Filter String

This setting is only visible if you select Worklist above.

Enter a string that you want to filter for, for example, a station name, station AET, modality, or an asterisk (*) to filter for all items.

Channel Naming

This setting is only visible if you select Worklist above.

Define which field you want to use to name the channels:

  • Station AET
  • Station Name
  • Modality

Debug Options

Debug Options

Debug Options

Setting

Description

Result Handling

Define what PRTG does with the sensor result:

  • Discard result (default): Do not store the sensor result.
  • Store result: Store the sensor result and the last response in the \Logs\sensors subfolder of the PRTG data directory on the probe system. The file names are Result of Sensor [ID].txt, Result of Sensor [ID].Data.txt, and Result of Sensor [ID].log. This setting is for debugging purposes. PRTG overwrites these files with each scanning interval.

i_podThis option is not available when the sensor runs on the hosted probe of a PRTG Hosted Monitor instance.

i_round_blueIn a cluster, PRTG stores the result in the PRTG data directory of the master node.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how this sensor shows different channels:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you select Stack channels on top of each other above.

Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status.

Query Entry Time Avg.

The average query entry time

Query Entry Time Max.

The maximum query entry time

Query Entry Time Min.

The minimum query entry time

Total

The total number of items found

i_round_blueThis channel is the primary channel by default.

Total Time

The total time of the C-FIND request or MWL query

i_round_blueThis sensor also adds channels for the number of items in each field it finds.

More

i_square_blueKNOWLEDGE BASE

Which .NET version does PRTG require?

What security features does PRTG include?