The SSH Script Advanced sensor connects to a Linux/Unix system via Secure Shell (SSH) and executes a script file that is located on the target system. This option is available as part of the PRTG API.
SSH Script Advanced Sensor
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
Sensor in Other Languages
Dutch: SSH Script Geavanceerd
French: Script avancé (SSH)
German: SSH-Skript (Erweitert)
Japanese: SSH スクリプト(詳細)
Portuguese: Script (avançado) (SSH)
Russian: Расширенный скрипт SSH
Simplified Chinese: 高级 SSH 脚本
Spanish: Script (avanzado) (SSH)
Remarks
Consider the following remarks and requirements for this sensor:
Remark
Description
Performance impact
This sensor has a very high performance impact. We recommend that you use no more than 50 of this sensor on each probe.
File storage
For security reasons, this sensor requires that you store the script file in the /var/prtg/scriptsxml directory on the target system. Make sure that the script has executable rights.
Credentials
This sensor requires credentials for Linux/Solaris/macOS (SSH/WBEM) systems in the settings of the parent device.
Distributions
This sensor does not support all Linux/Unix and macOS distributions.
Channels
This sensor does not officially support more than 50 channels.
Enter a description for Placeholder 1, for example information about the purpose or content of the placeholder.
Placeholder 1
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder1 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 2 Description
Enter a description for Placeholder 2, for example information about the purpose or content of the placeholder.
Placeholder 2
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder2 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 3 Description
Enter a description for Placeholder 3, for example information about the purpose or content of the placeholder.
Placeholder 3
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder3 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 4 Description
Enter a description for Placeholder 4, for example information about the purpose or content of the placeholder.
Placeholder 4
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder4 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 5 Description
Enter a description for Placeholder 5, for example information about the purpose or content of the placeholder.
Placeholder 5
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder5 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Sensor Settings
Sensor Settings
Setting
Description
Script
Select a script file from the dropdown list. It shows all script files that are available in the /var/prtg/scriptsxml directory on the target Linux/Unix system. For a script file to appear in this list, store the target file in this directory.
Make sure that the script has executable rights.
To show the expected sensor value and status, your files must return the expected XML or JSON format to standard output stdout. The values and message must be embedded in the XML or JSON.
For more information on how to create custom sensors and for the return format, see section Custom Sensors.
You cannot change this value after sensor creation.
Parameters
If your script file catches command-line parameters, define them here. You can also use placeholders. Enter a string or leave the field empty.
For a full list of all placeholders, see section Custom Sensors.
In SSH scripts, you can use alphanumeric characters and the special characters ".", "_", "-", "=", and "/" outside of quoted strings.
Mutex Name
Define a mutual exclusion (mutex) name for the process. Enter a string or leave the field empty.
PRTG runs all custom script sensors that have the same mutex name serially (not simultaneously). This is useful if you use a lot of sensors and want to avoid high resource usage caused by processes that run running at the same time.
Define a timeout in seconds for the connection. This is the time that the sensor waits to establish a connection to the host. Keep this value as low as possible. Enter an integer.
Make sure that the connection timeout is a value that is higher than the shell timeout to avoid potential errors.
Shell Timeout (Sec.)
Define a timeout in seconds for the shell response. This is the time in seconds the sensor waits for the shell to return a response after it has sent its specific command (for example, cat /proc/loadavg). The maximum value is 300 seconds (5 minutes). Enter an integer.
Make sure that the shell timeout is a value that is lower than the connection timeout to avoid potential errors.
SSH Port Inheritance
Define which port this sensor uses for the SSH connection:
Inherit from parent device (default): Use the SSH engine that you defined in the parent device settings or higher up in the object hierarchy. If you have not changed the SSH engine, this is the recommended option.
Default: This is the default SSH engine. It provides the best performance and security. It is set by default in objects that are higher up in the hierarchy, so usually you can keep the Inherit from parent device (default) option.
Compatibility mode (deprecated): Use this only if the default SSH engine does not work on a target device. The compatibility mode is the SSH engine that PRTG used in previous versions. It is deprecated. We will remove this legacy mode soon, so try to get your SSH sensors to run with the default SSH engine.
We strongly recommend that you use the default SSH engine.
The option you select here overrides the selection of the SSH engine in a higher object: a parent device, group, probe, or root.
Result Handling
Define what PRTG does with the sensor result:
Discard result (default): Do not store the sensor result.
Store result: Store the sensor result and the last response in the \Logs\sensors subfolder of the PRTG data directory on the probe system. The file names are Result of Sensor [ID].txt, Result of Sensor [ID].Data.txt, and Result of Sensor [ID] (SSHv2).txt. This setting is for debugging purposes. PRTG overwrites these files with each scanning interval.
Store result in case of error: Store the last sensor result only if the sensor shows the Down status.
This option is not available when the sensor runs on the hosted probe of a PRTG Hosted Monitor instance.
In a cluster, PRTG stores the result in the PRTG data directory of the master node.
Sensor Display
Sensor Display
Setting
Description
Primary Channel
Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.
You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab.
Graph Type
Define how this sensor shows different channels:
Show channels independently (default): Show a graph for each channel.
Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic. You cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).
Stack Unit
This setting is only visible if you select Stack channels on top of each other above.
Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.
Inherited Settings
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel
Description
Downtime
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status.
Execution Time
The execution time
[Value]
The values that the script file returns in several channels
For more information about the return value format, see section Custom Sensors.
More
KNOWLEDGE BASE
Which encryption algorithms do PRTG SSH sensors support?