<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: WMI Event Log Sensor

The WMI Event Log sensor monitors a Windows log file via Windows Management Instrumentation (WMI).

i_round_blueYou can individually set the sensor to a specific status according to a new event log entry.

WMI Event Log Sensor

WMI Event Log Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: WMI Logboek
  • French: Journal des événements (WMI)
  • German: WMI Ereignisprotokoll
  • Japanese: WMI イベントログ
  • Portuguese: Log de eventos (WMI)
  • Russian: Журнал событий WMI
  • Simplified Chinese: WMI 事件日志
  • Spanish: Registro de eventos (WMI)

Remarks

Consider the following remarks and requirements for this sensor:

Remark

Description

Performance impact

This sensor has a very high performance impact. We recommend that you use no more than 50 of this sensor on each probe.

WoW64

This sensor requires WoW64 (Windows 32-bit on Windows 64-bit) for target systems that run Windows Server 2016.

Credentials

This sensor requires credentials for Windows systems.

IPv6

This sensor supports IPv6.

Knowledge Base

Hosted probe

i_podYou cannot add this sensor to the hosted probe of a PRTG Hosted Monitor instance. If you want to use this sensor, add it to a remote probe device.

Basic Sensor Settings

Basic Sensor Settings

Basic Sensor Settings

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • wmieventlogsensor

i_square_cyanFor more information about basic sensor settings, see section Sensor Settings.

WMI Event Log Monitor

WMI Event Log Monitor

WMI Event Log Monitor

Setting

Description

Log File

The Windows log file that this sensor monitors.

Result Handling

Define what PRTG does with the sensor result:

  • Discard result (default): Do not store the sensor result.
  • Store result: Store the sensor result and the last response in the \Logs\sensors subfolder of the PRTG data directory on the probe system. The file names are Result of Sensor [ID].txt and Result of Sensor [ID].Data.txt. This setting is for debugging purposes. PRTG overwrites these files with each scanning interval.

i_round_blueIn a cluster, PRTG stores the result in the PRTG data directory of the master node.

Filter Event Log Entries

i_square_cyanFor more information and how to find out the correct filter, see the Knowledge Base: My Event Log sensor ignores changes in the event log. What can I do?

Filter Event Log Entries

Filter Event Log Entries

Setting

Description

Event Type

Specify the type of event that this sensor processes:

  • Any
  • Error
  • Warning
  • Information
  • Security Audit Success
  • Security Audit Failure

i_round_blueThe sensor cannot process other event types.

Filter by Source

Filter all received events for a certain event source:

  • Disable (default): Do not filter events.
  • Enable: Filter events.
    i_round_blueThe sensor only processes messages that match the value that you define below.

Filter Type

This setting is only visible if you select Enable above.

Select the filter type:

  • Include filter: Include the specified value and disregard all other values.
  • Exclude filter: Exclude the specified value and regard all other values.

Match String (Event Source)

This setting is only visible if you select Enable above.

Enter an event source that you want to filter for. Depending on the kind of filter, the sensor either processes the event source (Include filter option) or it does not process it (Exclude filter option). Enter a string.

Filter by ID

Filter all received events for a certain event ID:

  • Disable (default): Do not filter events.
  • Enable: Filter events.
    i_round_blueThe sensor only processes messages that match the value that you define below.

Filter Type

This setting is only visible if you select Enable above.

Select the filter type:

  • Include filter: Include the specified value and disregard all other values.
  • Exclude filter: Exclude the specified value and regard all other values.

Match Values (Event ID)

This setting is only visible if you select Enable above.

Enter an event ID that you want to filter for. Depending on the kind of filter, the sensor either processes the event ID (Include filter option) or it does not process it (Exclude filter option).

i_round_blueThe WMI Event Log supports more than one event ID. You can enter a comma-separated list of event IDs to filter for more than one ID. For example, 1100,4627,4747,4884,5050,6422.

Filter by Category

Filter all received events for a certain event category:

  • Disable (default): Do not filter events.
  • Enable: Filter events.
    i_round_blueThe sensor only processes messages that match the value that you define below.

Filter Type

This setting is only visible if you select Enable above.

Select the filter type:

  • Include filter: Include the specified value and disregard all other values.
  • Exclude filter: Exclude the specified value and regard all other values.

Match String (Event Category)

This setting is only visible if you select Enable above.

Enter a category that you want to filter for. Depending on the kind of filter, the sensor either processes the event category (Include filter option) or it does not process it (Exclude filter option). Enter a string.

Filter by User

Filter all received events for a certain event user:

  • Disable (default): Do not filter events.
  • Enable: Filter events.
    i_round_blueThe sensor only processes messages that match the value that you define below.

Filter Type

This setting is only visible if you select Enable above.

Select the filter type:

  • Include filter: Include the specified value and disregard all other values.
  • Exclude filter: Exclude the specified value and regard all other values.

Match String (Event User)

This setting is only visible if you select Enable above.

Enter a user name that you want to filter for. Depending on the kind of filter, the sensor either processes the event user (Include filter option) or it does not process it (Exclude filter option). Enter a string.

Filter by Computer

Filter all received events for a certain event computer:

  • Disable (default): Do not filter events.
  • Enable: Filter events.
    i_round_blueThe sensor only processes messages that match the value that you define below.

Filter Type

This setting is only visible if you select Enable above.

Select the filter type:

  • Include filter: Include the specified value and disregard all other values.
  • Exclude filter: Exclude the specified value and regard all other values.

Match String (Event Computer)

This setting is only visible if you select Enable above.

Enter a computer name that you want to filter for. Depending on the kind of filter, the sensor either processes the event computer (Include filter option) or it does not process it (Exclude filter option). Enter a string.

Filter by Message

Filter all received events for a certain event message:

  • Disable (default): Do not filter events.
  • Enable: Filter events.
    i_round_blueThe sensor only processes messages that match the value that you define below.

Filter Type

This setting is only visible if you select Enable above.

Select the filter type:

  • Include filter: Include the specified value and disregard all other values.
  • Exclude filter: Exclude the specified value and regard all other values.

Match String (Event Message)

This setting is only visible if you select Enable above.

Enter a message that you want to filter for. Depending on the kind of filter, the sensor either processes the event message (Include filter option) or it does not process it (Exclude filter option). Enter a string.

i_round_blueYou must use the percent sign (%) as wildcard for any or no character if you want to check if the string is part of the message. Otherwise, the whole event message must match the string. For example, you can enter %RAS% for any event message that contains the string RAS.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, PRTG displays the last value of the primary channel below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how this sensor shows different channels:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you select Stack channels on top of each other above.

Select a unit from the list. PRTG stacks all channels with this unit on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status.

New Records

The number of new records

i_round_blueThis channel is the primary channel by default.

More

i_square_blueKNOWLEDGE BASE

My Event Log sensor ignores changes in the event log. What can I do?

How can I configure sensors using speed limits to keep the status for more than one interval?

What security features does PRTG include?

My WMI sensors don't work. What can I do?